Environment:
- DR-Series
- DR-I6212WRX
Procedure:
Diagram setup:
Note: External devices require their own power source
- Go to the "Setup" icon on the front panel console.
- Click on DEVICE>Setup>Source and select the Camera" "Channel (camera #)" Sub Channel 1"
- Click "Apply" to save.
- Next Click Event>Additional Event>Setup Click the plus
- Click "Ok" to add
- Click on the "Action" field, then "Alarm-Out"
- Check 1 AO 1 (uncheck if lock will be open manually ) and NVR AO 1, Then Click "Ok"
Note: (AO-1 camera- N/O) (NVR AO 1 N/O on the NVR) - Click "Apply" to save the setting.
- Test by pressing the door button.