Environment:
- Rise Series
Purpose:
- 1st time setup
Procedure:
Please refer to CostarHD website for detailed installation and operation manuals, and safety instructions at: http://www.costarhd.com/Support/Product-Documentation
Check Before You Begin
- The network connection between the PC and the camera is normal.
- Your PC IP address is on the same subnet as the cameras default IP settings listed below
- The PC monitor display resolution is set to 1920 x 1080 or higher
Factory Default IP Address and Settings
IP Address: 192.168.2.150
Subnet Mask: 255.255.255.0
Gateway: 192.168.2.1
Factory Default User Names and Passwords
Access Level: Administrator
Username: admin
Password: no password
- In a browser (Google,Firefox,Edge) enter the ip address, and a "Create administrator user" prompt will appear.
- Upon logging in for the first time as admin, you are asked to create a password. Enter and re-enter a desired password and click Save New User. You are then asked to login using your password.
Initial Configuration - Set IP Address: In the left pane, Setup tab, click System then select Network Settings, and enter IP address settings.
Note: For the camera and the computer to communicate with each other, both have to be in the same subnet. So before setting the camera’s IP address, it is important to set the computer’s IP address to the same subnet.
Establishing Video Connection - Once logged in, the user interface appears.